Products
Description
1. Control several boilers at the same time. According to the loading amount to decide the number of the boilers operating, in order to produce a stable steam pressure, steam quality, improve fuel saving and also to provide ultimate boiler efficiency.
2. Can be connected to the Zu How maintenance centre to diagnose the condition of the boiler operation and assist to eliminate the malfunction.
3. Monitor the operation of several boilers at the same time and keep the records of the malfunction time, the position, the amount of evaporation, the amount of fuel consumption, the amount of feed water the steam pressure, the water2 tube temperature, the exhaust temperature, the feed water temperature.
Specification
MODEL | ME-1000G | ME-1000G1 | ME-1000G2 | ||||
---|---|---|---|---|---|---|---|
PERFORMANCE | EQUIVALENT OUTPUT | kg/h | 1000 | ||||
HEAT OUTPUT | kcal/h | 539000 | |||||
HEATING SURFACE AREA | m2 | 9.9 | |||||
MAX. PRESSURE | kgf/cm2 | 10 | |||||
WATER CONTENT | L | 176 | |||||
BOILER EFFICIENCY | % | 92 | 94 | 96 | |||
WATER PREHEATER | - | INCLUDE | |||||
COMBUSTION TYPE | - | TWO-STAGE | |||||
FUEL CONSUMPTION | 13A | Nm3/h | 59.2 | 57.9 | 56.7 | ||
LPG | PROPANE | kg/h | 51.1 | 50 | 49 | ||
BUTANE | L/h | 53.7 | 52.6 | 51.5 | |||
POWER OF EQUIPMENT | kw | 3.9 | |||||
POWER OF AUXILIARY EQUIPMENT | WATER PUMP MOTOR | kw | 1.5 | ||||
EXHAUSTING FAN MOTOR | 2.2 | ||||||
CONTROL PANEL | 0.2 | ||||||
PRODUCT WEIGHT | kg | 1820 | |||||
PIPE DIAMETERS | FUEL INLET DIAMETER | 13A | mm | 40 | |||
LPG | 40 | ||||||
FEED WATER INLET DIAMETER | 20 | ||||||
STEAM OUTLET DIAMETER | 50 | ||||||
BOILER-WATER DRAIN DIAMETER | 25 | ||||||
SAFETY VALVE OUTLET DIAMETER | 32 | ||||||
AUTO BLOWDOWN DIAMETER | 10 | ||||||
CHIMNEY DIAMETER | ψmm | 330 | |||||
POWER WIRE INLET DIAMETER | mm2 | 5.5 | |||||
SIZE | BOILER DIMENSIONS |
LENGTH | mm | 2040 | |||
WIDTH | 1250 | ||||||
HEIGHT | 2222 |
NOTES: | |
1. | ME-***G indicates gas Network Controlled Steam Boiler. |
2. | Standard power is 3Phase/220V/60HZ. Notice of change is required. |
3. | Fuel consumption is calculated at low heat value: 13A 9900 kcal/Nm3. LPG 11460 kcal/kg. |
4.
|
(1000kg/h~2000kg/h model) gas supply pressure 0.8~3.5kgf/cm2. Installation of pressure reducing device, gas entrance to the boiler to reduce 400~1000mmAq. ※Low pressure supply should be stable, depressurization can't be too much, and the gas flow should be enough. |
5. | Partial product modification for improvement is allowed without notice. |