Products
Description
Structural characteristics
Ultra-foot capacity, overloading ability
The non-contact voltage regulator can be 100% load continuous use, and can withstand inductive load transient. That will not damage the equipment and reduced life.
Better efficiency, excellent characteristics
The use of high magnetic beam, low iron loss Silicon steel slitting loss to no-load, no-load current to a minimum, all contained in the use of the most efficient, high-performance play a regulator to reduce power losses.
No intermittent voltage adjustment
Make use of voltage adjustment induction principle, no contact in a linearmovements in the load pressure adjustment voltage adjustment will not generate noise coupling and pressure drop, to load input power quality and the same.
Sturdiness and durability, and long service life Induction for the main internal voltage regulators, voltage regulators, without any contact components and component wear, and its main structure for the pallet, Shell, coil, formed by Silicon steel slitting, surges, the impact can be nonlinear load bear, strong, durable, as the main feature of life of up to 10 years.
Broad scope of AC power input
System design can withstand a wide voltage input range, in a poor environment AC input power can still work, all the components have been selected, high voltage transient resistance and the current.
Simple maintenance and maintenance
Internal modular design, all components are standardized criteria, and the main part of the coil structure, as long as it maintains normal external clean, without any maintenance and maintenance.
Tolerate harsh environment
Using high efficiency and the safety of large parts of the combination of industrial-grade, can tolerate poor temperature, humidity, vibration and pollution filthy environment.
Small size, light weight
The introduction of the new patent process technology and high-strength structural design of a new patent with precision machining, to make the products of smaller size, less weight, and achieve maximum capacity.
Features
System features automatic power
When the system automatically choose the power function, the power regulator after 5 S automatic voltage regulator output will be delayed.
Automatic emergency power system function
When the regulator failure or input range can not be beyond the scope of the rated voltage regulator, as long as the output voltage does not exceed the rated voltage of ± 10%, regulators continue to automatically load electricity, when the output voltage exceeds the rated voltage of ± 10% , will automatically cut off power supply load and issued alerts when regulators returned to the rated output voltage of ± 10% voltage within the scope of the time, delay after 5 S automatic restoration of electricity.
Overload and short-circuit protection
When the load in excess of its own regulator can withstand the capacity (more than the rated capacity), and output short circuit in the state, the regulator automatically cut load.
Wrong phase sequence protection
System phase sequence protection, to allocate code switching function of the choice of whether, when choosing a phase sequence protection, if the phase sequence should disconnect the output error, and issued alerts when the correct phase sequence automatically after the restoration of electricity When the removal of the function, regardless of whether the correct phase sequence can be normal output.
Dual insurance penthouse Control System
The regulator and the regulator circuit detection circuit, in addition to the original interlocking device, plus a monitor protection circuit, the output voltage can be fully and to ensure that the protection of the normal functions of action.
System (regulator) and remote telemetry (standard)
Remote part of the regulator to provide electrical isolation of the dynamic contact (1 A/60VDC contact rated capacity) to provide telemetry and regulator of the electrical isolation of DC (0-5) V or DC (0 ~ 20) mA / (4 ~ 20) mA signal standards.
Emergency manual bypass
Regulators are equipped with regulators, shutdown, the bypass switch when the regulator there can not automatically resume the serious faults be rectified, will switch to the power grid position, regulators work to emergency bypass state .
Output voltage undervoltage, high-voltage protection function testing
System with a separate undervoltage detection output voltage, output voltage of the high-voltage circuit, and load characteristics and visual equipment set upper and lower limits, when the output voltage regulator undervoltage, high pressure, the system will issue a warning, and cut off output load electricity, when the output voltage, high-pressure phenomena resume normal range, the system power output.
Lack of protection
Lack of a system of protection circuit, if the lack of case, disconnect the output load and issued alerts when missing after the resumption of the power output automatically.
Main structure with over-temperature detection coil
With the temperature structure of the coil, when the coils are produced by the abnormal Overheating or aging, can be rapidly detected to facilitate the rapid drop in maintenance or replacement of the coil, and a warning display.
Humanized anti-circuit maloperation
To prevent the misuse of human negligence and touch switches, the output power activated or improper power, specifically designed to control double bond, we must press the button only two power output, we must press the button, it closed two output power.
System (regulator) and remote telemetry (Advanced)
The system has RS232 or RS485/RS422 communication interface.
Telemetry: input voltage, input current, output voltage, output current.
Remote: working condition (normal / fault, work / bypass, and phase sequence normal / abnormal), input overvoltage, undervoltage input, input flow, lack of output, coil Overheating.
Specification
Input
|
Voltage range |
~ 15% ± 40% can be customized |
Panel displays |
Input phase voltage line |
Reading three-phase LED Display |
Applicable frequency |
45~65Hz |
Output phase voltage line |
Reading three-phase LED Display |
||
Applied load |
Resistor, inductive, capacitive are applicable |
Output phase current line |
Reading three-phase LED Display |
||
Output |
Regulators rate |
± 1% to ± 5% can be set |
High Voltage Output |
LED Display |
|
Voltage Regulators |
Rated voltage input can be ± 10% set |
Output undervoltage |
LED Display |
||
Reaction time |
± 10% voltage change ≤ 1 S |
Output overload |
LED Display |
||
Equipment Efficiency |
>95% |
Lack of output |
LED Display |
||
Overload capacity |
100% for 10 minutes of 200% for one minute |
Input error phase |
LED Display |
||
Control and protection |
High Voltage Protection |
Alarm output power |
Overheating coils |
LED Display |
|
Undervoltage protection |
Alarm output power |
Automatic bypass |
LED Display |
||
Lack of protection |
Alarm output power |
Manual bypass |
LED Display |
||
Wrong phase protection |
Alarm output power |
Operational Mode |
LED Display |
||
Coil over-temperature protection |
Alarm output power |
Application environment |
Temperature |
-10℃~50℃ | |
Overload protection |
Alarm output power |
Humidity |
0 ~ 95% non-condensed state |
||
Short-circuit protection |
Alarm output power |
Noise |
Whole ≤ 65 dB (from M Box 1) |
||
Automatic bypass |
Possess |
Cooling |
Cooled heat | ||
Manual bypass |
Possess |
Places |
Indoor use (outdoor use can be customized) |
||
Mandatory Surge |
Possess |
Standards |
Insulation voltage |
YD/T1325-2004 standard reference implementation |
|
Automatic / manual operation mode |
Possess |
Insulation Resistance |
YD/T1325-2004 standard reference implementation |
||
Ground Resistance |
YD/T1325-2004 standard reference implementation |
||||
Creepage distance |
YD/T1325-2004 standard reference implementation |
||||
Coil rating |
F (155 ℃) | ||||
Packaging |
Sealed wooden box packaging |