Products
● High Quality
1. Double Conversion True On-line UPS with zero transformer time
2. Industrial grade UPS
3. IGBT/PWM technology, small volume, low noise and high reliable
4. Microcomputer control, high efficiency and accuracy
● Safe
1. Bypass Switch Switching
2. Indepentdent three phase inverter, ableto support 100% unbalance loading.
3. Isolated Rectifier& Battery Charger. Load current will not be affected when input power returns.
4. EMI/ RFI and overload protection
5. Static Two-way Switch
6. Protecting for overload and shout citcuit.
7. With output and input isolated transformer in order to prevent noise and lightening suit for SMI/ AI/ BGA precision equipment.
8. Static bypass and amintentance bypass are satandard features, allowing the UPS to 9. maintain power even during high overload or maintenance.
9. Cold start funtion. The UPS can be started with battery for emergent power on.
● Flexibility
1. 12 Pulse communicator to lower input current harmonics
2. Expandable battery (option)
3. RS-232 communication port and SNMP management are available on request.
● Simple
1. Module design is easy to maintain
2. LED/ LCD faceplate
3. small size, save time, energy and space
Description
Static Type UPS (On Line) uses charger to offer battery electricity. Inverter produces sine AC for load. When AC is interrupted, inverter produces sine AC for load by battery.
- English LCD system, displaying UPS working flow chart, working value and guiding operating indication.
- Illustration by computer’s speech sound system.
- If the battery is over-discharged the life for normal use is then reduced; for the purpose of protecting the battery, which is provided with double check protects including special designed circuits with function of automatic shut down, and avoiding inverse connection and short circuit happened.
- Exploiting IGBT power component to achieve the function of less volume, low noise and high reliability.
- ONE-TOUCH button makes turn on more convenient.
- On Line design, without interruption of power suddenly.
Specification
Model | CTL-1000 | CTL-1500 | CTL-2000 | CTL-3000 | CTL-6000 | CTL-10000 | |
Capacity | 800W | 1200W | 1600W | 2400W | 4800W | 8000W | |
Input | Low Line Transfer | 160VAC±5% or 80VAC±5% (Full load) | 176VAC±3%(Full load) | ||||
110VAC±5% or 50VAC±5% (Half load) | 110VAC±3%(Half load) | ||||||
Low Line Comeback | 175VAC±5% or 85VAC±5% (Full load) | 186VAC±3%(Full load) | |||||
120VAC±3%(Half load) | |||||||
High Line Transfer | 300VAC±5% or 150VAC±5% | 300VAC±3% | |||||
High Line Comeback | 290VAC±5% or 145VAC±5% | 290VAC±3% | |||||
Frequency Range | 40 ~ 70 HZ | 46 ~ 54HZ or 56 ~ 64HZ | |||||
Phase | Single Phase with ground | ||||||
Power Factor | >=0.99 (Full load) | ||||||
Output | Voltage | 208 / 220 / 230 / 240 VAC or 110 / 115 / 120 / 127 VAC | 208/220/230/240 VAC | ||||
Voltage Regulation | ±3% (Batt. Mode) | ±1% (Batt. Mode) | |||||
Frequency Range (AC Mode) | 47 ~ 53 HZ or 57 ~ 63 HZ | 46 ~ 54HZ or 56 ~ 64HZ | |||||
Frequency Range (Batt. Mode) | 50 ± 0.25 HZ or 60 ± 0.3 HZ | 50 ±0.1HZ or 60 ±0.1HZ | |||||
Overload | 100% ~ 110% : Audible Warning | ||||||
110% ~ 130% : Transfers to bypass mode when the utility is normal / Shuts down in 30 seconds at battery mode | |||||||
>130% : Transfers to bypass mode when the utility is normal / Shuts down immediately at battery mode | |||||||
Current Crest Ration | 3:1 | ||||||
Harmonic Distortion | <=3% (linear load) | <=4% (linear load) | <=3% (linear load) | ||||
<=6% (non-linear load) | <=7%(non-linear load) | <=6%(non-linear load) | |||||
Transfer Time | AC Mode -> Batt. Mode : 0ms | ||||||
Batt. Mode -> Bypass : 4ms | Batt. Mode -> Bypass : 0ms | ||||||
Wavefrom (Batt. Mode) | Pure Sine Wave | ||||||
Efficiency | AC Mode | 85% | 88% | 89% | |||
Bttery Mode | 83% | 88% | |||||
Alarm | Battery Mode | Sounding every 4 seconds | |||||
Low Battery | Sounding every seconds | ||||||
Overload | Sounding twice every second | ||||||
Fault | Continuously sounding | ||||||
Indicator | LCD Display | UPS Status, Load Level, Battry Level, Input/ Output Voltage, Discharging Time, Fault | |||||
Battery | Battery Type | 12 / 7AH | 12V / 9AH | 12V / 7AH | 12V / 9AH | 12V / 7AH | 12V / 9AH |
Numbers | 3 | 3 | 6 | 6 | 20 | 20 | |
Recharge Time(Recover to 90% capacity) | 4 Hours | 7 Hours | 9 Hours | ||||
Max Charging Current | 1.0 A | ||||||
Charging Voltage | 41.0VDC±1% | 82.1VDC±1% | 273VDC±1% | ||||
Communication | RS-232 or USB | Support WIN 2000 / 2003 / XP / 2008/7 , Linux, MAC | |||||
SNMP(optional) | Power management from SNMP manger | ||||||
Environment | Temperature | 0 ~ 40 °C | |||||
Himidity | 20 ~ 90% (Non-condensing) | ||||||
Noise (Less than 1 meter) | 45 DB | 55 DB | 58DB | ||||
Dimension | mm | 397 x 145 x 220 | 421 x 190 x 318 | 592 x 250 x 576 | |||
Weight | Kgs | 13 | 14 | 26 | 28 | 81 | 83 |