JAKI ENTERPRISE CO., LTD.
886-4-24915501
886-4-24954240
No.11, Lane 2, Rencih St., Dali City, Taichung County 41282, Taiwan
www.jaki.com.tw

Products

Static Switching Units.
Capacitors Dedicated Static Switching Units for APFR.
JK3PSZT3-XXXXX

1. The static switching modules of the JK3PSZT3 series are the basic building block for the construction of static capacitor banks for power factor correction purposes. These capacitor banks use thyristors instead of the classic contactors for the connection of each large group of capacitors and they are ideal in installations where the leakage current suffers quick and large fluctuations (load changes in intervals that can range from split seconds to 8 or 10 seconds).

2. The static switching units of the JK3PSZT3 Series have been designed to connect and disconnect capacitors in milliseconds. They can be used to build capacitors with various steps, or for the individual compensation of a load that must be compensated instantly due to connection / disconnection deficiencies, for example, in welding units, cranes, lifts, etc.

3. Automatic capacitor banks with static system - JK3PSZT3 Series
The JK3PSZT3 Series capacitor banks with static system have been designed for Power factor correction purposes in networks with fluctuating loads. The variations in power are relatively fast (in milliseconds) so that the switching operations are carried out by thyristors, which are connected to a voltage control board, so that the connection and disconnection of the capacitor is carried out with a zero voltage difference. Transients are prevented between the connection and disconnection of steps, obtaining the immediate response to the load fluctuations.

4. Functions and advantages of capacitor banks with a static system. The functions or advantages of this compensation system are as follows:Immediate response to the compensation request. The response time of the Power factor correction can be of a single network frequency cycle, thus achieving an almost instantaneous compensation. Elimination of start-up transients produced by the capacitor's connection. The connection takes place when the voltage network matches that of the capacitor when it is partially or totally loaded, as seen Fig.1.

Capacitors Dedicated Static Switching Units for APFR. Phase-splitting compensation. static switching modules

Feature
  •  It has R.S.T. one phase’s fuse wire broken LED light, and offer a output point for abnormal condition, also can be emergency control for the system.
  • The static switching units of the JK3PSZT3 series have been designed to connect and disconnect capacitors in milliseconds.

Safety/Quality Approvals

3ø3W
JK3PSZT3-22035, JK3PSZT3-22050, JK3PSZT3-22060, JK3PSZT3-22080, JK3PSZT3-22100, 
JK3PSZT3-22125, JK3PSZT3-22160, JK3PSZZT3-22180, 
JK3PSZT3-22225, JK3PSZT3-22250, 
JK3PSZT3-22300, JK3PSZT3-22350, JK3PSZT3-22400.

JK3PSZT3-48035, JK3PSZT3-48050, JK3PSZT3-48060, JK3PSZT3-48080, JK3PSZT3-48100, 
JK3PSZT3-48125, JK3PSZT3-48160, JK3PSZT3-48180, 
JK3PSZT3-48225, JK3PSZT3-48250, 
JK3PSZT3-48300, JK3PSZT3-48350, JK3PSZT3-48400.

JK3PSZT3-60035, JK3PSZT3-60050, JK3PSZT3-60060, JK3PSZT3-60080, JK3PSZT3-60100, 
JK3PSZT3-60125, JK3PSZT3-60160, JK3PSZT3-60180, 
JK3PSZT3-60225, JK3PSZT3-60250, 
JK3PSZT3-60300, JK3PSZT3-60350, JK3PSZT3-60400

Specification

  • Main power: AC 208~240V/ 380~480V/ 500~600V ±10%
  • Auxiliary voltage: AC 220V±15% 50/60Hz
  • Rated current: 35A 50A 60A 80A 100A 125A 160A 180A 225A 250A 300A 350A 400A
  • Work frequency: 47~63Hz
  • Output type: Zero crossing
  • Input control signal: 
    * Each phase DC control (12-24VDC).
    * Output range: 0~100%
  • Environment: -10°C~50°C Humidity Under 90% RH.
  • Insulation resistance: Over 20 MΩ (power & external cover) Over 20 MΩ (input signal & external cover).
  • Strength of press-resisted: 2500VAC/1min between power & external cover 1000VAC/1min between power & external cover.

 